When the boiler is shut down, the temperature of the heat transfer oil can be reduced to below 70 ℃ before the shutdown of the hot oil pump. In case of sudden power failure, extinguish the fire immediately, and then implement the operating procedures. Otherwise, the furnace tube will be burned out and the loss will be large. According to the type of heat transfer oil boiler, heat transfer oil shall be reasonably selected to prevent overheating. Heilongjiang Horizontal gas steam generator When purchasing unqualified heat transfer oil, do not save money or mix heat transfer oil indiscriminately. Otherwise, the consequences will be very serious. Prevent the oxidation of heat transfer oil. The strict heat transfer oil is more than 50 degrees in contact with the air, which will make the heat transfer oil crack. Its speed is amazing, and the consequences are relatively serious. After normal operation, the test crew needs to close the exhaust valve on the auxiliary exhaust pipe. After 6 months of use, the heat transfer oil must be sampled and tested according to the instructions. If problems are found, the heat transfer oil must be replaced immediately. small-scale Horizontal gas steam generator how much However, it should be noted that different types of heat transfer oil should not be mixed. The circulation speed of the heat transfer oil should not be less than 1.5m/s. Due to the excessive temperature difference between some entrances and exits, the original design requirements were destroyed, the heat transfer oil could not maintain the original circulation state, the boundary layer became thicker, and the thermal resistance became larger, making the furnace wall exceed the oil film temperature, leading to carbon deposition, cracking, polymerization, coking, and even burning through the furnace tube.
Oil gas boilers have obvious characteristics. The main fuel is oil or gas. According to their functions, they can be divided into steam boilers and hot water boilers. Most of them are designed with large furnaces, with thermal efficiency of more than 98%. At the same time, they also have the characteristics of fully automatic and safe operation. Heilongjiang Horizontal gas steam generator Generally speaking, oil and gas boilers adopt excellent boiler body design. WNS horizontal boiler adopts wet back three return structure, which can reduce the exhaust gas temperature and make the boiler thermal efficiency reach more than 90%. Therefore, the combustion efficiency is relatively high, greatly extending its service life. small-scale Horizontal gas steam generator how much In addition, in the design of oil and gas boiler, there are often hinged front and rear smoke boxes. The maintenance method is simple. Most of them are insulated with light aluminum silicate fiber to reduce heat loss. The external use of all stainless steel plate skin improves the appearance quality. In addition, the oil and gas boiler is equipped with an excellent combustion machine, which greatly improves its stability. The combustion machine has an automatic purging function, It can also prevent deflagration during ignition.
Biomass boilers need green new energy. Compared with other boilers, biomass boilers have the following four major advantages: one boiler is multi-purpose, and can cook, boil water, and bathe while heating. Strong conversion system, low starting heat transfer temperature and fast heat transfer speed. Heilongjiang Horizontal gas steam generator Low installation cost, safe heating: the equipment is universal, without changing the original heating equipment, and the pipes and radiators are universal. Water circulation is used to achieve a wide range of heating materials, which will never be exhausted. It can be taken everywhere (such as rice husks, corn stalks, rice stalks, wheat). Safety and environmental protection: low working pressure, cooking, water boiling, bathing, heating, etc., and it is also suitable for burning boilers, greenhouse heating Large area heating and small and medium-sized hotels can be used all year round without seasonal restrictions. small-scale Horizontal gas steam generator how much The reason why the ignition of biomass boiler is difficult is that the stable small fire signal cannot be established, which is caused by the failure of the small fire detector to detect the fire normally. The flame detector for small fire is ionization type flame detector, which requires a contact area with the flame, stable flame size, and gas pressure controlled within a strict range.
High heat exchange efficiency. The fusion rate at the contact is more than 95%, the contact thermal resistance is small, and the thermal conductivity is good. Low flow resistance. Heilongjiang Horizontal gas steam generator Since H-shaped finned tubes are similar to square structures, after being assembled into heat exchangers, the tubes are divided into many small channels by fins, which has a certain uniform effect on the air flow. The air flow is similar to longitudinal downstream flow, and the air flow resistance is relatively small. However, spiral finned tubes have strong air flow disturbance, high turbulence, and large air flow resistance due to the directivity of the fins. Less ash. The flue gas contains fly ash, which is easy to deposit on the windward side and leeward side of the pipe bundle. The H-shaped fin tube bundle has the characteristics of uniform flow and downstream flow, so it is not easy to cause serious local ash deposition, and the fly ash can be taken away with the air flow in time. Therefore, compared with spiral finned tube heat exchanger, H-type finned tube heat exchanger has less ash deposition. small-scale Horizontal gas steam generator how much Small size and low weight. H-shaped finned tube has high area expansion rate, less ash deposition, and high heat transfer efficiency. When the heat transfer capacity is equal, the space occupied by the heat exchanger can be small. For reconstruction projects, the heat exchange area can be arranged as much as possible in the limited space to reduce the exhaust gas temperature, improve the waste heat recovery efficiency, or increase the maintenance space to facilitate maintenance.
As a pressure vessel, waste heat boiler shall be used reasonably and managed scientifically in the process of use to avoid safety accidents caused by improper use and management. The quality of water is one of the important factors affecting the service life and safe operation of waste heat boiler. The quality of water added into the boiler directly affects the normal operation of waste heat boiler. Heilongjiang Horizontal gas steam generator The normal delivery of water is the lifeblood of normal boiler use. If the boiler is short of water, it is bound to cause major safety accidents and fatal damage to the boiler. Therefore, it is necessary to ensure continuous and stable water transmission during boiler operation. small-scale Horizontal gas steam generator how much Regardless of the tonnage of the waste heat boiler, the lower configuration of the boiler electric control shall ensure the continuous operation of the boiler water pump, and the water supply pipeline shall be equipped with a water supply regulating valve with good regulation characteristics to control the water supply flow according to the level of the boiler. In addition, in order to ensure that the normal delivery of water will not be affected by the pump failure, a standby pump should be ensured.
Most softened water equipment can only slow down the scale growth rate, but can not achieve the purpose of scale prevention. The water quality used by different users varies greatly in different regions. Heilongjiang Horizontal gas steam generator In some construction sites, steam generators are used for steam maintenance of bridges because tap water cannot be used due to conditions. Only groundwater or river water can be used. At present, the hardness of many groundwater in China exceeds the standard, and the total hardness of water in some areas is high. small-scale Horizontal gas steam generator how much It can reach several hundred millimoles, which is quite serious. I think the use of water softener is basically ineffective, because ordinary resin exchange water softener can only affect water with hardness of 7, which also ensures the use process. It needs to be cured regularly.