夜上海最新论坛

 //pinpaicloud.cn/data/upload/202006/20200606175354_603.jpg
Your current location: home page > Hot information

Tianjin Vertical Electric Heating Steam Generator Factory

2021-01-07
 Tianjin Vertical Electric Heating Steam Generator Factory

The existing industrial boiler flue gas waste heat recovery equipment mainly includes tubular heat exchanger and full heat pipe heat exchanger. Tube and tube heat exchanger can be composed of finned tube bundles. The advantage of finned tube is that it can withstand higher temperature, but has low heat transfer coefficient and large floor area. Tianjin Electrically heated steam generator The flue gas of industrial boilers contains sulfur and other acidic substances. In the low temperature zone (flue gas outlet section), the temperature may be lower than the dew point of the acidic substances. The acidic substances will dew on the pipe wall, corrode the shell of the fin tube. The fin tube heat exchanger has poor operating reliability and low service life. vertical Electrically heated steam generator factory The total heat pipe heat exchanger of boiler flue gas waste heat recovery equipment is composed of heat pipe bundles. Its shell is made of multi-layer composite materials. The heat pipe structure is complex, the cost is relatively expensive, the service life is short, and the steel consumption is large. It is difficult for users to accept it, and it is difficult to promote its application in production. The composite heat pipe heater not only takes into account the heat exchange effect, but also takes into account the economic affordability of the investors in production, which is particularly suitable for the current situation in China's industrial production.

 Tianjin Vertical Electric Heating Steam Generator Factory

Biomass boilers can be roughly divided into two categories according to their uses: one is biomass thermal energy boiler, and the other is biomass electric energy boiler. Tianjin Electrically heated steam generator In fact, the principle of the two is basically the same. Both obtain energy by burning biomass fuel, which is just one way to directly obtain heat energy. The second way is to convert heat energy into electric energy. Among the two boilers, one is widely used and has mature technology. If we continue to subdivide, one kind of boiler - biomass heat energy boiler mainly has the following two types: one is small biomass heat energy boiler. vertical Electrically heated steam generator factory The boiler uses solidified or gasified biomass fuel to provide heat energy in the form of hot water. Its advantages are small size, simple structure and low price; Class II: medium-sized biomass heat energy boiler. Such boilers mainly use solidified biomass fuel to provide hot water or steam. Its advantages are relatively mature technology, small energy loss and strong heat supply capacity.

 Tianjin Vertical Electric Heating Steam Generator Factory

The starting of gas-fired boiler shall be carried out according to the operating procedures. The following is the accurate starting process of the analyzed gas-fired boiler: turn on the main power supply, start the gas-fired incinerator, and close the vent valve on the drum when it emits steam. Tianjin Electrically heated steam generator Check the manhole, handhole flange and valve of the gas boiler. If any leakage is found, fasten them. If leakage occurs after fastening, shut down the boiler for maintenance. When the gas pressure of the gas boiler rises by 0.05~0.1MPA, make up water, blow down, check the experimental water supply system and blow down equipment, and flush the water level gauge together. When the gas boiler pressure rises to 0.1~0.15MPA, flush the pressure gauge trap; When the gas pressure of the gas-fired boiler rises to 0.3MPA, turn the "load high fire/low fire" knob to "high fire" to strengthen incineration. When the pressure of the boiler rises to 2/3 of the operating pressure, start pipe warming and air supply, slowly open the main steam valve to prevent water hammer. vertical Electrically heated steam generator factory When the drain valve emits steam, close it. After all the drain valves are closed, slowly open the main gas valve to fully open, and then reverse it for half a circle. Turn the "Control of gas incinerator" knob to the automatic gear.

 Tianjin Vertical Electric Heating Steam Generator Factory

Waste heat boilers are widely used in high energy consumption industries. There are two common types of waste heat boilers: one is used to recover the exhaust gas emitted by ordinary boilers, such as fuel fired and gas-fired boilers, biomass fired boilers, etc. The temperature of the exhaust gas from ordinary boilers is about 600 ℃, which is not too high, Therefore, the requirements for waste heat recovery boiler are relatively low. Tianjin Electrically heated steam generator The other is industrial waste heat recovery boiler, such as building materials industry, chemical industry, steel making industry, etc. The temperature of waste gas and waste heat in these industries is high, and the recovery and utilization is also very valuable. vertical Electrically heated steam generator factory Henan Yuji Boiler Vessel Manufacturing Co., Ltd., founded in 2005, is located at No. 8, Jizhong Road, Xiaoji Town, Xinxiang County, Henan Province. It is a comprehensive enterprise of boiler and pressure vessel, mainly engaged in the manufacturing of boilers and pressure vessels, with technological innovation as the core, integrating the design, manufacturing, sales, installation, transformation and maintenance of boilers and pressure vessels.

 Tianjin Vertical Electric Heating Steam Generator Factory

The waste heat boiler has advantages in the subdivided industry and is the leading enterprise in the industry. The company's main products are various types of waste heat boilers, industrial boilers, power station boilers, nuclear power equipment and power station auxiliaries. It is a research, development, design and manufacturing base for waste heat boilers with large scale and complete varieties in China. Tianjin Electrically heated steam generator Waste heat boiler is a typical energy-saving and emission reduction equipment. Its heat source can come from high-temperature flue gas waste heat, chemical reaction waste heat, combustible waste gas waste heat, and even can use high-temperature product waste heat. At present, the company has more than 20 series and more than 100 varieties of waste heat boiler products, which are widely used in steel, building materials, power, nonferrous metals, coking, chemical and other industries. vertical Electrically heated steam generator factory In 2008, the company produced 272 sets of waste heat boilers of various types, with a total of 10268 steam tons, accounting for 34% of the comprehensive market share based on steam tons; According to the output value, the market share is 47%, ranking first in the waste heat boiler industry.

 Tianjin Vertical Electric Heating Steam Generator Factory

Effectively prevent and reduce low temperature corrosion of air preheater. Low temperature corrosion is caused by sulfur dioxide generated by combustion of sulfur in fuel. Tianjin Electrically heated steam generator Under the action of catalyst, sulfur dioxide is further oxidized to sulfur trioxide. Sulfur trioxide and water vapor in the flue gas generate sulfuric acid vapor, which greatly increases the dew point of the flue gas, condenses the sulfuric acid vapor on the flue gas side of the preheater tube wall, causing sulfuric acid corrosion of the preheater. The content of sulfur trioxide has a great impact on the corrosion rate of the preheater. The content of sulfur trioxide is not only related to the sulfur content in the fuel, but also related to the oxygen content in the flue gas. vertical Electrically heated steam generator factory Low oxygen combustion can significantly reduce the oxygen content in flue gas, greatly reduce the amount of sulfur dioxide oxidized to sulfur trioxide, reduce the dew point of flue gas, and effectively reduce the corrosion of preheater. Low oxygen combustion reduces the amount of flue gas. It can not only reduce the exhaust gas temperature, improve the boiler efficiency, but also reduce the power consumption of the forced draft fan and the wear of the heating surface.