The waste heat boiler is composed of drum, movable smoke hood, feeding pipe groove, oxygen lance mouth, furnace mouth section flue, inclined section 1 flue, inclined section 2 flue, last section 1 flue, last section 2 flue, nitrogen sealing device and nitrogen sealing plug, manhole, micro differential pressure tapping device, flue support and hanger. Shenyang Gas steam generator Unlike conventional boilers, waste heat boilers do not produce combustion process and do not have combustion related equipment. Essentially, they are just gas water/steam heat exchangers. The waste heat boiler is divided into six circulation loops. Each circulation loop is composed of downcomer and riser. The feed water of each section of flue is introduced from the drum through downcomer to the lower header of each flue, and then enters into each heating surface. The water passes through the heating surface and generates steam into the header, and then is introduced into the drum through the riser. vertical Gas steam generator manufactor The needle tube waste heat recovery device is a special high-efficient energy-saving product specially designed for waste heat recovery of flue gas. The heat recovery boiler uses needle shaped tubes to strengthen the heat elements to expand the heating surface. The heating surface on the water pipe smoke side can be greatly increased. At the same time, the smoke will form strong turbulence when passing through the needle shaped tube surface, which will improve the heat transfer efficiency and reduce the soot accumulation.

The starting of gas-fired boiler shall be carried out according to the operating procedures. The following is the accurate starting process of the analyzed gas-fired boiler: turn on the main power supply, start the gas-fired incinerator, and close the vent valve on the drum when it emits steam. Shenyang Gas steam generator Check the manhole, handhole flange and valve of the gas boiler. If any leakage is found, fasten them. If leakage occurs after fastening, shut down the boiler for maintenance. When the gas pressure of the gas boiler rises by 0.05~0.1MPA, make up water, blow down, check the experimental water supply system and blow down equipment, and flush the water level gauge together. When the gas boiler pressure rises to 0.1~0.15MPA, flush the pressure gauge trap; When the gas pressure of the gas-fired boiler rises to 0.3MPA, turn the "load high fire/low fire" knob to "high fire" to strengthen incineration. When the pressure of the boiler rises to 2/3 of the operating pressure, start pipe warming and air supply, slowly open the main steam valve to prevent water hammer. vertical Gas steam generator manufactor When the drain valve emits steam, close it. After all the drain valves are closed, slowly open the main gas valve to fully open, and then reverse it for half a circle. Turn the "Control of gas incinerator" knob to the automatic gear.

Most softened water equipment can only slow down the scale growth rate, but can not achieve the purpose of scale prevention. The water quality used by different users varies greatly in different regions. Shenyang Gas steam generator In some construction sites, steam generators are used for steam maintenance of bridges because tap water cannot be used due to conditions. Only groundwater or river water can be used. At present, the hardness of many groundwater in China exceeds the standard, and the total hardness of water in some areas is high. vertical Gas steam generator manufactor It can reach several hundred millimoles, which is quite serious. I think the use of water softener is basically ineffective, because ordinary resin exchange water softener can only affect water with hardness of 7, which also ensures the use process. It needs to be cured regularly.

When the boiler is shut down, the temperature of the heat transfer oil can be reduced to below 70 ℃ before the hot oil pump is shut down. In case of sudden power failure, extinguish the fire immediately, and then implement the operating procedures. Otherwise, the furnace tube will be burned out and the loss will be large. According to the type of heat transfer oil boiler, heat transfer oil shall be reasonably selected to prevent overheating. Shenyang Gas steam generator When purchasing unqualified heat transfer oil, do not save money or mix heat transfer oil indiscriminately. Otherwise, the consequences will be very serious. Prevent the oxidation of heat transfer oil. The strict heat transfer oil is more than 50 degrees in contact with the air, which will make the heat transfer oil crack. Its speed is amazing, and the consequences are relatively serious. After normal operation, the test crew needs to close the exhaust valve on the auxiliary exhaust pipe. After 6 months of use, the heat transfer oil must be sampled and tested according to the instructions. If problems are found, the heat transfer oil must be replaced immediately. vertical Gas steam generator manufactor However, it should be noted that different types of heat transfer oil should not be mixed. The circulation speed of the heat transfer oil should not be less than 1.5m/s. Due to the excessive temperature difference between some entrances and exits, the original design requirements were destroyed, the heat transfer oil could not maintain the original circulation state, the boundary layer became thicker, and the thermal resistance became larger, making the furnace wall exceed the oil film temperature, leading to carbon deposition, cracking, polymerization, coking, and even burning through the furnace tube.

The fluctuation of waste heat boiler flue gas in flow, temperature, composition, dust content and other aspects is one of its characteristics. The nature of the fluctuation can be regular, periodic, or irregular, aperiodic; The characteristics of fluctuation can be gradual. Shenyang Gas steam generator It can also be impulsive; It can be a single parameter or a composite fluctuation of multiple parameters. The selection of waste heat boiler shall first analyze the whole cycle of the main process flow, and determine the flue gas characteristics of each time section in the cycle. vertical Gas steam generator manufactor Therefore, corresponding measures shall be implemented one by one in the design of waste heat boiler. The prominent feature is often the main basis for the selection of waste heat boiler.