
The starting of gas-fired boiler shall be carried out according to the operating procedures. The following is the accurate starting process of the analyzed gas-fired boiler: turn on the main power supply, start the gas-fired incinerator, and close the vent valve on the drum when it emits steam. Xinxiang Electrically heated steam generator Check the manhole, handhole flange and valve of the gas boiler. If any leakage is found, fasten them. If leakage occurs after fastening, shut down the boiler for maintenance. When the gas pressure of the gas boiler rises by 0.05~0.1MPA, make up water, blow down, check the experimental water supply system and blow down equipment, and flush the water level gauge together. When the gas boiler pressure rises to 0.1~0.15MPA, flush the pressure gauge trap; When the gas pressure of the gas-fired boiler rises to 0.3MPA, turn the "load high fire/low fire" knob to "high fire" to strengthen incineration. When the pressure of the boiler rises to 2/3 of the operating pressure, start pipe warming and air supply, slowly open the main steam valve to prevent water hammer. small-scale Electrically heated steam generator manufactor When the drain valve emits steam, close it. After all the drain valves are closed, slowly open the main gas valve to fully open, and then reverse it for half a circle. Turn the "Control of gas incinerator" knob to the automatic gear.

The waste heat boiler has advantages in the subdivided industry and is the leading enterprise in the industry. The company's main products are various types of waste heat boilers, industrial boilers, power station boilers, nuclear power equipment and power station auxiliaries. It is a research, development, design and manufacturing base for waste heat boilers with large scale and complete varieties in China. Xinxiang Electrically heated steam generator Waste heat boiler is a typical energy-saving and emission reduction equipment. Its heat source can come from high-temperature flue gas waste heat, chemical reaction waste heat, combustible waste gas waste heat, and even can use high-temperature product waste heat. At present, the company has more than 20 series and more than 100 varieties of waste heat boiler products, which are widely used in steel, building materials, power, nonferrous metals, coking, chemical and other industries. small-scale Electrically heated steam generator manufactor In 2008, the company produced 272 sets of waste heat boilers of various types, with a total of 10268 steam tons, accounting for 34% of the comprehensive market share based on steam tons; According to the output value, the market share is 47%, ranking first in the waste heat boiler industry.

The steam generator pressure controller is used to control the generator, because it has no water level display, no board control, and its heating control is mainly controlled by the floating water level controller. Xinxiang Electrically heated steam generator When the water level is moderate, the floating point is connected to the control voltage to operate and heat the AC contactor. The generator has a simple structure and is currently used in the market. The common non heating fault of this generator is mainly found in the float level controller. First check the external wiring of the float level controller, connect the upper and lower control lines, and then remove the float level controller to see if it is flexible. small-scale Electrically heated steam generator manufactor You can use the manual to use the meter to determine whether the upper control point and the lower control point can be connected. Check the equipment and check for water. The float can fill the fuel tank, replace the float, and eliminate faults.

Most people may already know something about flue gas waste heat recovery, because they have already explained a lot about it. In order to let you know the relevant knowledge of flue gas waste heat recovery, the following is a brief introduction to the two methods commonly used for recovery. Xinxiang Electrically heated steam generator Two methods are usually adopted for flue gas waste heat recovery: one is to preheat the workpiece; The other is to preheat air for combustion support. The flue gas preheating workpiece needs to occupy a large volume for heat exchange, which is often limited by the operation site (this method cannot be used for furnaces that are used intermittently). small-scale Electrically heated steam generator manufactor Preheating air for combustion support is a good method. It is generally configured on the heating furnace, which can also strengthen combustion, speed up the temperature rise of the furnace, and improve the thermal performance of the furnace. This can not only meet the requirements of the process, but also achieve significant comprehensive energy-saving effect.