The hardness of water is mainly formed and expressed by calcium and magnesium, so cation exchange resin (water softener) is generally used to replace Ca2+and Mg2+(the main component forming scale) in the water. With the increase of Ca2+and Mg2+in the resin, the efficiency of the resin to remove Ca2+and Mg2+gradually decreases. Guizhou Horizontal fuel gas steam generator When the resin absorbs a certain amount of calcium and magnesium ions, it must be regenerated. The regeneration process is to wash the resin layer with salt water in the salt tank to replace the hardness ions on the resin. With the regeneration waste liquid discharged out of the tank, the resin will resume its softening and exchange function. small-scale Horizontal fuel gas steam generator manufactor Because the hardness of water is mainly formed by calcium and magnesium and represents that the hardness of water is mainly formed by calcium and magnesium and represents the principle of sodium ion exchange softening treatment, which is to exchange the hardness components Ca2+and Mg2+in the water with the Na+in the resin by passing the raw water through the sodium cation exchange resin, so as to absorb Ca2+and Mg2+in the water and soften the water.
The steam generator pressure controller is used to control the generator, because it has no water level display, no board control, and its heating control is mainly controlled by the floating water level controller. Guizhou Horizontal fuel gas steam generator When the water level is moderate, the floating point is connected to the control voltage to operate and heat the AC contactor. The generator has a simple structure and is currently used in the market. The common non heating fault of this generator is mainly found in the float level controller. First check the external wiring of the float level controller, connect the upper and lower control lines, and then remove the float level controller to see if it is flexible. small-scale Horizontal fuel gas steam generator manufactor You can use the manual to use the meter to determine whether the upper control point and the lower control point can be connected. Check the equipment and check for water. The float can fill the fuel tank, replace the float, and eliminate faults.
As a large equipment, the maintenance of gas-fired hot blast stove is one of the things that must be done. Guizhou Horizontal fuel gas steam generator Regular maintenance can not only keep the hot blast stove clean, but also improve the service life of the hot blast stove. Therefore, it is the top priority in the use of hot blast stove. Today's editor will tell you how to maintain the hot blast stove regularly. In many manufacturers that use hot blast stoves, in order to better develop the enterprise, it is necessary to increase the number of hot blast stoves and improve the performance of hot blast stoves. small-scale Horizontal fuel gas steam generator manufactor When enterprises purchase hot blast stove equipment, they must understand their own needs and the products of hot blast stove manufacturers in the market. Therefore, the small edition of gas-fired hot blast stove tells us the problems to be considered in the selection of hot blast stove.
To understand the advantages and disadvantages of hot blast stove and hot water stove, we should start from the working principles of the two boilers. The hot water boiler can increase the indoor temperature by burning hot water, circulating hot water, heat dissipation, etc. General purpose (radiators, floor heating pipes, water heating air conditioners are generally used for heating in families, enterprises and institutions). Guizhou Horizontal fuel gas steam generator The hot blast stove can increase the indoor temperature by heating the air. Generally, a hot channel wind belt is required. It is generally used for workshop, breeding, planting and special heating or drying. Most areas in northern China are cold, such as the three northeastern provinces, Inner Mongolia, Xinjiang and other cities. The colder temperature is more than minus 40 degrees Celsius. There are hot water boilers and steam boilers for heating. Its disadvantage is that it is afraid of circulatory system failure or power failure. small-scale Horizontal fuel gas steam generator manufactor Once the power failure exceeds two to three hours, if the insulation is not good, the pipeline will freeze. The heating of hot blast furnace is not frozen, and the temperature can be set. It can save 40% energy than hot water heating and 50% energy than steam boiler heating. This comparison is practical. The hot blast stove does not need to apply for a use certificate, the steam boiler and pressure hot water boiler need to apply for a use certificate, and the functional department also needs to carry out annual inspection every year, but also has to bear the cost.
High heat exchange efficiency. The fusion rate at the contact is more than 95%, the contact thermal resistance is small, and the thermal conductivity is good. Low flow resistance. Guizhou Horizontal fuel gas steam generator Since H-shaped finned tubes are similar to square structures, after being assembled into heat exchangers, the tubes are divided into many small channels by fins, which has a certain uniform effect on the air flow. The air flow is similar to longitudinal downstream flow, and the air flow resistance is relatively small. However, spiral finned tubes have strong air flow disturbance, high turbulence, and large air flow resistance due to the directivity of the fins. Less ash. The flue gas contains fly ash, which is easy to deposit on the windward side and leeward side of the pipe bundle. The H-shaped fin tube bundle has the characteristics of flow equalization and downstream flow, which is not easy to cause serious local ash deposition, and the fly ash can be taken away with the air flow in time. Therefore, compared with spiral finned tube heat exchanger, H-type finned tube heat exchanger has less ash deposition. small-scale Horizontal fuel gas steam generator manufactor Small size and low weight. H-shaped finned tube has high area expansion rate, less ash deposition, and high heat transfer efficiency. When the heat transfer capacity is equal, the space occupied by the heat exchanger can be small. For reconstruction projects, the heat exchange area can be arranged as much as possible in the limited space to reduce the exhaust gas temperature, improve the waste heat recovery efficiency, or increase the maintenance space to facilitate maintenance.
The existing industrial boiler flue gas waste heat recovery equipment mainly includes tubular heat exchanger and full heat pipe heat exchanger. Tube and tube heat exchanger can be composed of finned tube bundles. The advantage of finned tube is that it can withstand higher temperature, but has low heat transfer coefficient and large floor area. Guizhou Horizontal fuel gas steam generator The flue gas of industrial boilers contains sulfur and other acidic substances. In the low temperature zone (flue gas outlet section), the temperature may be lower than the dew point of the acidic substances. The acidic substances will dew on the pipe wall, corrode the shell of the fin tube. The fin tube heat exchanger has poor operating reliability and low service life. small-scale Horizontal fuel gas steam generator manufactor The total heat pipe heat exchanger of boiler flue gas waste heat recovery equipment is composed of heat pipe bundles. Its shell is made of multi-layer composite materials. The heat pipe structure is complex, the cost is relatively expensive, the service life is short, and the steel consumption is large. It is difficult for users to accept it, and it is difficult to promote its application in production. The composite heat pipe heater not only takes into account the heat exchange effect, but also takes into account the economic affordability of the investors in production, which is particularly suitable for the current situation in China's industrial production.