In daily life, pressure vessels are divided into those in contact with fire sources and those not in contact with fire sources. In fact, pressure vessels also need anti-corrosion in daily life. For the anti-corrosion of pressure vessels, we need to do the following. Gansu Oil fired gas steam generator First, check the structure of its equipment components, safety valves, bursting discs, emergency vent valves and other collective Yixing pressure tanks to see if there is any corrosion. Once corrosion occurs, measures should be taken in a timely manner. Anti rust paint should be painted before the equipment is used. After use, it should be cleaned in a timely manner to ensure the cleanliness of the equipment. vertical Oil fired gas steam generator manufactor Secondly, it is necessary to protect the safety device of the pressure vessel. The safety device is an important device of the pressure vessel. Good protection should be carried out. Good maintenance should be carried out before and after use. It is necessary to apply lubricating oil and antirust paint.
When the boiler is shut down, the temperature of the heat transfer oil can be reduced to below 70 ℃ before the shutdown of the hot oil pump. In case of sudden power failure, extinguish the fire immediately, and then implement the operating procedures. Otherwise, the furnace tube will be burned out and the loss will be large. According to the type of heat transfer oil boiler, heat transfer oil shall be reasonably selected to prevent overheating. Gansu Oil fired gas steam generator When purchasing unqualified heat transfer oil, do not save money or mix heat transfer oil indiscriminately. Otherwise, the consequences will be very serious. Prevent the oxidation of heat transfer oil. The strict heat transfer oil is more than 50 degrees in contact with the air, which will make the heat transfer oil crack. Its speed is amazing, and the consequences are relatively serious. After normal operation, the test crew needs to close the exhaust valve on the auxiliary exhaust pipe. After 6 months of use, the heat transfer oil must be sampled and tested according to the instructions. If problems are found, the heat transfer oil must be replaced immediately. vertical Oil fired gas steam generator manufactor However, it should be noted that different types of heat transfer oil should not be mixed. The circulation speed of the heat transfer oil should not be less than 1.5m/s. Due to the excessive temperature difference between some entrances and exits, the original design requirements were destroyed, the heat transfer oil could not maintain the original circulation state, the boundary layer became thicker, and the thermal resistance became larger, making the furnace wall exceed the oil film temperature, leading to carbon deposition, cracking, polymerization, coking, and even burning through the furnace tube.
The waste heat boiler greatly improves the utilization rate of heat released by fuel combustion, so this kind of boiler saves energy; Fuel oil, gas and coal combustion generate high-temperature flue gas to release heat. The high-temperature flue gas first enters the furnace, then enters the waste heat recovery device of the front smoke box, then enters the pyrotechnic tube, and then enters the waste heat recovery device in the flue of the rear smoke box. The high-temperature flue gas turns into low-temperature flue gas and is discharged into the atmosphere through the chimney. Gansu Oil fired gas steam generator Conditions conducive to quick startup of waste heat boiler: (1) The waste heat boiler adopts forced circulation, which has the priority of quick startup. (2) The flue gas baffle is hydraulically controlled, which can be used to adjust the sky in principle. The flue gas flow into the boiler is reduced. (3) The adjustable guide vane at the inlet of gas turbine can not only adjust the flue gas flow of gas turbine, but also increase or decrease the exhaust gas temperature of gas turbine through the selection of IGV temperature control mode. (4) The steam turbine bypass is designed for the rated evaporation capacity of the boiler. (5) The welded bends and headers of each heating module of the boiler are in the boiler. (6) Similar boilers in other gas turbine power plants can not be reduced when starting, and can be used to adjust the main steam pressure of the boiler. Outside the wall, contact with high-temperature smoke is avoided. vertical Oil fired gas steam generator manufactor Operating experience of gas turbine load, such as simultaneous startup of gas turbine and waste heat boiler (flue gas damper fully open). Under the possibility of quick startup of waste heat boiler, the water level of steam drum and deaerator will lose control after the flue gas baffle is opened.
The hardness of water is mainly formed and expressed by calcium and magnesium, so cation exchange resin (water softener) is generally used to replace Ca2+and Mg2+(the main component forming scale) in the water. With the increase of Ca2+and Mg2+in the resin, the efficiency of the resin to remove Ca2+and Mg2+gradually decreases. Gansu Oil fired gas steam generator When the resin absorbs a certain amount of calcium and magnesium ions, it must be regenerated. The regeneration process is to wash the resin layer with salt water in the salt tank to replace the hardness ions on the resin. With the regeneration waste liquid discharged out of the tank, the resin will resume its softening and exchange function. vertical Oil fired gas steam generator manufactor Because the hardness of water is mainly formed by calcium and magnesium and represents that the hardness of water is mainly formed by calcium and magnesium and represents the principle of sodium ion exchange softening treatment, which is to exchange the hardness components Ca2+and Mg2+in the water with the Na+in the resin by passing the raw water through the sodium cation exchange resin, so as to absorb Ca2+and Mg2+in the water and soften the water.
What are the main applications of electric heating heat conduction oil boiler and steam generator in ironing industry, biochemical industry, school experimental heat source, food processing and other clothing industries? Gansu Oil fired gas steam generator Next, the manufacturer of heat conduction oil furnace will explain it to you. Low carbon emissions: even if coal is used as power generation energy, energy loss and vehicle pollution during coal transportation can be saved and reduced by promoting and improving the scale and intensity of coal power generation, so as to reduce carbon emissions as a whole and enhance the low-carbon performance of energy use. Low carbon life: ergonomically designed, it relates to an electric heating system represented by radiators, air conditioners and radiators and a wire heating system represented by heating cables. vertical Oil fired gas steam generator manufactor The new generation of electric boiler heating system represented by electric boiler is more suitable for people's living needs in the activity space. Low carbon economy: China vigorously develops energy conservation and power generation at low ebb. The general use and promotion of this heating method has directly promoted the strict inspection and lowering of 65% of China's statutory energy saving standards, thus promoting the development of low-carbon buildings in China. Low carbon energy: clean and renewable heating energy. In terms of coal, natural gas, straw, wood and other energy sources, electric energy is one of the promising hot energy sources. With the rise of solar energy, wind energy, hydropower, nuclear energy and other new energy sources, it is booming.
The steam generator pressure controller is used to control the generator, because it has no water level display, no board control, and its heating control is mainly controlled by the floating water level controller. Gansu Oil fired gas steam generator When the water level is moderate, the floating point is connected to the control voltage to operate and heat the AC contactor. The generator has a simple structure and is currently used in the market. The common non heating fault of this generator is mainly found in the float level controller. First check the external wiring of the float level controller, connect the upper and lower control lines, and then remove the float level controller to see if it is flexible. vertical Oil fired gas steam generator manufactor You can use the manual to use the meter to determine whether the upper control point and the lower control point can be connected. Check the equipment and check for water. The float can fill the fuel tank, replace the float, and eliminate faults.