The furnace liner is the combustion chamber of the horizontal gas-fired heat transfer oil furnace. The burner nozzle is placed in the front of the furnace liner, and the high-temperature flue gas generated by combustion extends to the rear, leaving the furnace liner and returning to the space. Generally, the number of times of returning is not more than four, and the common one is the three return heat conduction oil furnace. Jinan Horizontal steam generator This type of heat transfer oil furnace can be divided into dry back type heat transfer oil furnace and full wet back type heat transfer oil furnace according to the structure of the flue gas reentry space at the rear of the furnace. The flue gas reentry space of the dry back heat conduction oil furnace is enclosed by refractory materials; The flue gas reentry space of the full wet back type heat conduction oil furnace is composed of a recuperative chamber immersed in water. In addition, there is a central regenerative heat conduction oil furnace: that is, the back wall of the furnace liner is sealed inside the boiler shell, and the flue gas is turned back to the front from the inner wall around the furnace liner after encountering. This type of heat transfer oil furnace can also be regarded as a full wet back heat transfer oil furnace. vertical Horizontal steam generator how much Although the dry back heat transfer oil furnace is simple in structure, the refractory material at the rear of the furnace liner is easily damaged, and the rear tube plate is often directly washed by high temperature flue gas. The temperature difference is large, so the dry back heat transfer oil furnace is obsolete. At present, few manufacturers produce it; Although the full wet back heat conduction oil furnace has a complex structure, it avoids the problem of flue gas sealing in the reentry space and is suitable for micro positive pressure combustion.
As is known to all, the boiler using sensible heat of various waste gases and waste heat after waste incineration as heat source is called waste heat boiler, also called waste heat boiler. Therefore, the country advocates vigorously developing waste heat utilization, energy conservation and emission reduction, which plays a positive role in protecting energy and improving the quality of human living environment. Jinan Horizontal steam generator In the design of waste heat boiler, how to reasonably divide the temperature range is the basis for reasonably arranging the heating surface of waste heat boiler and making maximum use of waste heat. Under the condition of a given exhaust gas temperature at the inlet of the waste heat boiler, there are two requirements for the exhaust gas temperature. One is to limit the exhaust gas temperature, which is required to be within a reasonable range; The other is that the exhaust gas temperature is not limited, requiring greater use of waste heat. vertical Horizontal steam generator how much In either case, for medium and low temperature waste heat utilization, the narrow point temperature difference directly affects the evaporation capacity of the waste heat boiler and the layout of the heating surface. Narrow point temperature difference, also known as node temperature difference, is a small temperature difference between evaporator outlet flue gas and heated saturated water vapor during heat exchange. With the change of narrow point temperature difference, the relative total heat exchange area, relative evaporation capacity and relative exhaust gas temperature of the waste heat boiler also change.
The waste heat boiler has advantages in the subdivided industry and is the leading enterprise in the industry. The company's main products are various types of waste heat boilers, industrial boilers, power station boilers, nuclear power equipment and power station auxiliaries. It is a research, development, design and manufacturing base for waste heat boilers with large scale and complete varieties in China. Jinan Horizontal steam generator Waste heat boiler is a typical energy-saving and emission reduction equipment. Its heat source can come from high-temperature flue gas waste heat, chemical reaction waste heat, combustible waste gas waste heat, and even can use high-temperature product waste heat. At present, the company has more than 20 series and more than 100 varieties of waste heat boiler products, which are widely used in steel, building materials, power, nonferrous metals, coking, chemical and other industries. vertical Horizontal steam generator how much In 2008, the company produced 272 sets of waste heat boilers of various types, with a total of 10268 steam tons, accounting for 34% of the comprehensive market share based on steam tons; According to the output value, the market share is 47%, ranking first in the waste heat boiler industry.
Inspection and use preparation of oil and gas boiler. Inspection of the furnace and flue, and the soot and sundries in the furnace and flue shall be removed. Jinan Horizontal steam generator Check the boiler accessories to see if they are in good condition; Whether the cock can rotate easily; Whether the instruments and control devices are in good condition and clean. After inspection, the pressure gauge cock shall be in working condition. Check the automatic control system. Check the auxiliary equipment of oil and gas boiler. Check the combustion equipment to see if the combustion equipment is in good condition; For mechanical transmission system, coal handling system and ballast system, the test steering is normal; The spring of the gearbox shall be properly compressed and lubricated; The indication of coal door gauge is correct. vertical Horizontal steam generator how much The eagle iron is neat and complete, and the ballast plate is complete. Check the heating surface and ensure that the equipment coupling is firmly connected; V-belt is loose properly; The lubricating oil is in good condition; The cooling water is smooth. After passing the test, install the protective cover, test run separately, and pay attention to the current during idling.
The steam used in the steam generator of the hotel laundry is usually 0.4~0.6MPa saturated steam. The working temperature of steam is not very high. Jinan Horizontal steam generator The steam boiler of the hotel requires high steam efficiency due to operating costs, so it can save operating costs. The area of the hotel is relatively limited, so the steam boiler with small floor area must be selected. In order to control the investment cost and heat loss of the steam pipe, the steam boiler is usually placed on the side of the laundry room. vertical Horizontal steam generator how much The steam equipment in the hotel laundry room can only be turned on when washing, not when washing. Therefore, the steam generator is required to start steam production quickly. Laundry equipment is sometimes opened a lot and sometimes less, so the steam boiler is required to adjust the steam volume within the specified range.
System oil drainage: circulate the heat transfer oil between 120 ± 5 to drain the heat transfer oil in the system (if you do not replace the oil, please find a clean container to store it properly). Prepare an appropriate amount of coke removal cleaning agent for the heat transfer oil system, drain the oil in the gas-fired heat transfer oil boiler system, and disconnect the cleaning system from the oil storage tank (close the valve), including the connection between the high-level tank and the oil storage tank. Jinan Horizontal steam generator Residual oil blowing steps: connect the air compressor at the pressure gauge or other places that can be connected, boost the system to 0.3-0.4MPa, and discharge it instantaneously; Repeat this process until the residual oil is blown out. The gas-fired heat transfer oil boiler, circulating pump, and other heat users form a cleaning circulating circuit for decoking and cleaning: add diluted cleaning agent to the system and fill it up to 1/2 of the water level of the high-level tank. Dosage of coke removal cleaning agent: 10~20%, the specific dosage shall be determined according to the scale thickness. Temperature: 90-95, time: 12-72 hours, which can be determined according to the scale thickness. Rinsing and cleaning: after cleaning, drain the residual liquid in the system and add clean water to rinse twice until the coke remover is free of foam and the water is clear. vertical Horizontal steam generator how much Temperature: 85-95, time: 5-8 hours Water blowing steps: after cleaning, connect the air compressor at the pressure gauge or other places that can be connected, use compressed air to boost the system to 0.3-0.4 MPa, and vent at each low point. Repeat this process until the water is blown out. Waste liquid treatment: the cleaning waste liquid generated in the cleaning process is discharged after being treated in the biochemical tank.