Pressurized light water boiler nuclear power plant transfers heat generated in nuclear fuel to Steam generator The supply water supplied from the secondary side is heated and converted into steam, and the steam is used to mechanically work in the turbine to generate electricity.

On the secondary side of the steam generator, there is a large flow of supply water including corrosion products of the system structure, which causes phase change and changes into steam. At this time, because the flow rate decreases, the iron corrosion products included in the supply water precipitate in the lower part of the secondary side of the steam generator.

 Steam generator

Among the iron corrosion products, hematite and magnetite account for 95.8%, and others are composed of other metal oxides. Under the effect of this iron corrosion product, the corrosion of steam generator heat transfer tubes is promoted. In particular, the iron corrosion products accumulated on the support plate of the heat transfer tube blocked the flow path of the cooling water and caused the water level oscillation of the steam generator, which became the reason for the output reduction or sudden suspension of nuclear power.

As the iron corrosion product of this sediment, hundreds of kg are accumulated in the lower part of the steam generator every year. Therefore, in order to remove the corrosion products accumulated at the lower part of the steam generator, the removal operation is carried out during the preventive maintenance period of each scheme after the operation of the steam generator drainage system. However, because the iron oxide is consolidated at the bottom of the steam generator, it is difficult to remove it with the drainage system.