The gas and steam generator manufacturer will analyze the common faults and solutions of the generator for you

2020-06-09 11:35:12
second

Gas steam generator It is mainly composed of two parts, namely heating part and water injection part. Gas steam generator manufacturer The heating part is divided into electric contact pressure gauge to control heating and pressure controller to control heating. The water injection part is divided into manual water injection and water pump water injection.

1. If the ignition fails and the air pressure is normal, the ignition will not occur.

Troubleshooting measures: (1) replace, (2) reinstall or replace, (3) readjust.

2. I. The automatic water injection generator does not inject water.

Troubleshooting: (1) Check whether the pump motor has power supply or phase failure to make it normal. Check whether the water pump relay has power supply and make it normal. (2) The circuit board does not output power to the relay coil. Replace the circuit board. (3) Check whether the high water level electrode is well connected with the shell, and whether the end point is rusted to make it normal. Check the water pump pressure and motor speed, repair the water pump or replace the motor.

For generators that use float level controller to inject water, in addition to checking the power supply, check whether the low water level contact of the float level controller is rusted or connected reversely, and it will be normal after repair.

3. Connect the power supply, press Start, and the motor will not rotate.

Troubleshooting measures: (1) Adjust the air pressure to the specified value (2) Clean or repair the solenoid valve pipe connector (3) Press reset to check whether the element is damaged and the motor current (4) Check whether the water level, pressure and temperature exceed the limit.

4. The automatic water injection generator keeps filling water:

Troubleshooting measures: (1) Check that the voltage of the control water level electrode of the circuit board is abnormal. If it is abnormal, the circuit board needs to be replaced; (2) Repair the high water level electrode to solve the problem of poor contact; (3) It is also necessary to check whether the high water level contact of the liquid level controller is in good contact, and then check whether the float floats or the float tank is flooded. If it is abnormal, replace it.