夜上海最新论坛

 Steam generator manufacturer
Your current location: home page > News > common problem

The steam generator manufacturer briefly describes the maintenance contents of the electrically heated steam generator

2020-10-10 10:11:32
second

Now as a steam equipment Electrically heated steam generator It is widely used for disinfection and drying. Users hope that the equipment can run for a long time. Therefore, in addition to standardized operation, they should also pay attention to its daily maintenance in the process of use, so as to prevent problems before they happen. Next year, we will introduce to you which parts of the equipment need to be repaired:

Manufacturer of electric heating steam generator Check whether the heating device is in good condition; The safety spring of the speed governing box shall be properly compressed and well lubricated. In order to ensure the normal and safe operation of the generator and extend the service life of the equipment, the medium water should be clean, non corrosive, and free of impurities. Generally, soft water after water treatment or water filtered by filter tank is used.

The sundries in the furnace should be cleaned. The air duct regulating valve and gate shall be complete and tight, with accurate opening and closing indication and flexible opening and closing. In order to ensure that there is no or less scale in the cylinder and the cylinder operates normally, it must be cleaned once every 300 hours of operation, including electrodes, electric heating elements, cylinder inner walls and connectors.

Electric heating Steam generator The inspection of accessories depends on whether the safety accessories are in good condition, whether the cock rotates flexibly, and all kinds of control devices and instruments should be complete and kept clean. After passing the inspection, the pressure gauge cock shall be in working condition. If the safety valve is found to be sluggish or stuck, it must be repaired or replaced before it can be put into operation again. The electrodes of the water level controller shall be cleaned regularly to prevent the electric control failure caused by electrode fouling. Use emery cloth to remove the scale on the electrode. This work must be carried out when the equipment has no steam pressure and the power supply is cut off.

in general, Electric heating steam generator plant home In order to ensure the safe operation of the generator, the generator must be regularly inspected. The items of regular inspection include the tightness of water level controller, electrical circuit, all valves and connecting pipes, the availability and maintenance, reliability and accuracy of various instruments. The pressure gauge, pressure relay, safety valve and generator shall be subject to safety inspection once a year, and the safety inspection shall be reported to the local labor department and carried out under its supervision.

 Manufacturer of electric heating steam generator


Recent browsing: