Vertical electric heating Steam generator After the power is connected, turn on the power knob, and the water pump will pump the water in the water tank into the heating cylinder of the steam generator. The water level will rise with the water supply of the water pump. When the water level is higher than the water level, the power supply of the electric heating tube will be automatically connected to start heating; At this time, when the water pump continues to supply water to the high water level, the water pump automatically stops supplying water. At the same time, under the continuous heating of the electric heating pipe, the water temperature in the heating cylinder keeps rising until the steam with the required working pressure is generated. At this time, the steam can be supplied by opening the exhaust valve. During the steam supply process, the steam pressure may continue to rise. When the pressure rises to 0.4Mpa, the pressure controller acts and automatically disconnects the power supply of the heating tube to stop heating. As the heating stops, the steam pressure in the cylinder gradually decreases. When the steam pressure drops to about 0.3Mpa, the power supply of the electric heating tube is connected again, and the steam pressure rises again, so that the steam source can be obtained continuously.
Installation of steam generator: try to install it in a place convenient for operation. The hot water pipeline should not be too long, and should have a good thermal insulation layer. The pipeline should be properly inclined from the hot steam output end to the end. The water supply source must be installed with a control valve. The power supply must be equipped with supporting control switch, fuse and reliable protective grounding wire, 380v three-phase four wire extension (or three-phase five wire extension), 220v single-phase power supply, and the wiring standard shall be in accordance with the power line section standard in the attached table. All wiring must comply with relevant regulations. The power supply voltage must be controlled within 5%, otherwise the use effect will be affected Steam generator supplier 380v voltage must be three-phase five wire power supply, and the zero line cannot be connected incorrectly. Energy conservation and emission reduction In terms of the textile industry, in addition to controlling pollution and emissions from fabric procurement, it is also necessary to start from the production point of view, electric steam generator, steam generator to generate steam to supply steam system, Vertical electric steam generator To measure and mitigate the impact of enterprises on the environment.
Abnormal protection function of steam generator power supply: the boiler stops running immediately. Leakage protection function of steam generator: the control system will automatically cut off the power supply after detecting the leakage of electric heating elements. Water shortage protection of steam generator: when the boiler is short of water, cut off the control circuit of the heating tube in time to prevent the heating tube from dry burning damage, and the controller sends out water shortage alarm indication. Abnormal protection function of steam generator power supply: the boiler stops running immediately.